Criterion agreement and 48-hour test–retest reliability of a microcontroller-based cadence counter during in-place running

Authors

DOI:

https://doi.org/10.58524/jcss.v5i4.1492

Keywords:

In-place running, Microcontroller, Measurement agreement, Running cadence, Test-retest reliability

Abstract

Background: Running cadence should be assessed with systems that demonstrate acceptable agreement with a reference method and adequate repeatability under the intended testing conditions.

Aim: To quantify criterion agreement with high-speed video and 48-hour test–retest repeatability of a microcontroller-based contact-mat cadence counter during controlled in-place running.

Methods: Thirty track and field athletes completed a 60-s in-place running trial on a microcontroller-based contact mat while synchronized 240-frames/s video was recorded. Independently reviewed and adjudicated video counts served as the criterion; contact-mat testing was repeated after 48 h. Agreement was assessed using ICC(A,1), absolute-error indices, and Bland–Altman statistics. Repeatability was quantified using ICC(A,1), SEM, MDC95, and session limits of agreement.

Results: Criterion ICC(A,1) was 0.995 (bootstrap 95% CI 0.990–0.997); MAE was 1.10 spm, RMSE was 1.40 spm, and MAPE was 0.63%. Mean device–video bias was −0.10 spm, with 95% limits of agreement from −2.89 to +2.69 spm. Test–retest ICC(A,1) was 0.990 (bootstrap 95% CI 0.979–0.995), with SEM of 1.44 spm and MDC95 of 3.98 spm.

Conclusions: The contact-mat counter yielded closely aligned aggregate cadence values and favorable short-interval repeatability in a fixed 60-s in-place task. These estimates are protocol-specific and do not establish interchangeability with overground running systems or performance in competition settings.

References

Anderson, L. M., Martin, J. F., Barton, C. J., & Bonanno, D. R. (2022). What is the effect of changing running step rate on injury, performance and biomechanics? A systematic review and meta-analysis. Sports Medicine - Open, 8, 112. https://doi.org/10.1186/s40798-022-00504-0

Baker, L. M., Yawar, A., Lieberman, D. E., & Walsh, C. J. (2024). Predicting overstriding with wearable IMUs during treadmill and overground running. Scientific Reports, 14, 6347. https://doi.org/10.1038/s41598-024-56888-4

Berzosa, C., Comeras-Chueca, C., Bascuas, P. J., Gutiérrez, H., & Bataller-Cervero, A. V. (2024). Assessing trail running biomechanics: A comparative analysis of the reliability of Stryd and GARMIN-RP wearable devices. Sensors, 24(11), 3570. https://doi.org/10.3390/s24113570

Cabrera-Linares, J. C., Martínez Salazar, C., Párraga Montilla, J. A., & Latorre Román, P. Á. (2025). Validation of Garmin HRM-Pro for assessment of spatiotemporal parameters during treadmill running: Agreement with three motion analysis systems. Sensors, 25(17), 5407. https://doi.org/10.3390/s25175407

Chase, C. J., Aguiar, E. J., Moore, C. C., Chipkin, S. R., Staudenmayer, J., Tudor-Locke, C., & Ducharme, S. W. (2023). Cadence (steps/min) as an indicator of the walk-to-run transition. Human Movement Science, 90, 103117. https://doi.org/10.1016/j.humov.2023.103117

Cudejko, T., Button, K., & Al-Amri, M. (2022). Validity and reliability of accelerations and orientations measured using wearable sensors during functional activities. Scientific Reports, 12, 14619. https://doi.org/10.1038/s41598-022-18845-x

DeJong Lempke, A. F., Audet, A. P., Wasserman, M. G., Melvin, A. C., Soldes, K., Heithoff, E., Shah, S., Kozloff, K. M., & Lepley, A. S. (2025). Biomechanical differences and variability during sustained motorized treadmill running versus outdoor overground running using wearable sensors. Journal of Biomechanics, 178, 112443. https://doi.org/10.1016/j.jbiomech.2024.112443

Donahue, S. R., & Hahn, M. E. (2022). Validation of running gait event detection algorithms in a semi-uncontrolled environment. Sensors, 22(9), 3452. https://doi.org/10.3390/s22093452

Donahue, S. R., & Hahn, M. E. (2023). Estimation of gait events and kinetic waveforms with wearable sensors and machine learning when running in an unconstrained environment. Scientific Reports, 13, 2339. https://doi.org/10.1038/s41598-023-29314-4

Goss, D. D., Xu, J., & Hertel, J. (2026). Effects of step rate based gait training on running biomechanics: A systematic review and meta-analysis. Gait & Posture, 123, 110009. https://doi.org/10.1016/j.gaitpost.2025.110009

Hu, X., Wang, G., & Ma, G. (2026). A wearable monitoring system for running gait analysis by diffusion transformer. PLOS ONE, 21(1), e0341066. https://doi.org/10.1371/journal.pone.0341066

Jones, B. D. M., Wheat, J., Middleton, K., Carey, D. L., & Heller, B. (2025). Reliability of running gait variability measures calculated from inertial measurement units. Journal of Biomechanics, 180, 112515. https://doi.org/10.1016/j.jbiomech.2025.112515

Jung, C. K., Kim, J., & Rhim, H. C. (2023). Validation of an ear-worn wearable gait analysis device. Sensors, 23(3), 1244. https://doi.org/10.3390/s23031244

Kelly, M., Jones, P., Wuebbles, R., Lugade, V., Cipriani, D., & Murray, N. G. (2022). A novel smartphone application is reliable for repeat administration and comparable to the Tekscan Strideway for spatiotemporal gait. Measurement, 192, 110882. https://doi.org/10.1016/j.measurement.2022.110882

Lacey, A., Whyte, E., O'Keeffe, S., O'Connor, S., & Moran, K. (2022). A qualitative examination of the factors affecting the adoption of injury focused wearable technologies in recreational runners. PLOS ONE, 17(7), e0265475. https://doi.org/10.1371/journal.pone.0265475

Manupibul, U., Tanthuwapathom, R., Jarumethitanont, W., Kaimuk, P., Limroongreungrat, W., & Charoensuk, W. (2023). Integration of force and IMU sensors for developing low-cost portable gait measurement system in lower extremities. Scientific Reports, 13, 10653. https://doi.org/10.1038/s41598-023-37761-2

Mason, R., Pearson, L. T., Barry, G., Young, F., Lennon, O., Godfrey, A., & Stuart, S. (2023). Wearables for running gait analysis: A systematic review. Sports Medicine, 53(1), 241-268. https://doi.org/10.1007/s40279-022-01760-6

Mason, R., Barry, G., Hall, G., Godfrey, A., & Stuart, S. (2024). Validity and reliability of running gait measurement with the ViMove2 system. PLOS ONE, 19(10), e0312952. https://doi.org/10.1371/journal.pone.0312952

Mason, R., Celik, Y., Barry, G., Godfrey, A., & Stuart, S. (2025). Instrumenting Parkrun: Usefulness and validity of inertial sensors. Sensors, 25(1), 30. https://doi.org/10.3390/s25010030

Meingast, T., Carrier, B., Melvin, A., Kozloff, K. M., DeJong Lempke, A. F., & Lepley, A. S. (2025). Limited interchangeability of smartwatches and lace-mounted IMUs for running gait analysis. Sensors, 25(17), 5553. https://doi.org/10.3390/s25175553

Mora-Gonzalez, J., Gould, Z. R., Moore, C. C., Aguiar, E. J., Ducharme, S. W., Schuna, J. M., Jr., Barreira, T. V., Staudenmayer, J., McAvoy, C. R., Boikova, M., Miller, T. A., & Tudor-Locke, C. (2022). A catalog of validity indices for step counting wearable technologies during treadmill walking: The CADENCE-adults study. International Journal of Behavioral Nutrition and Physical Activity, 19, 117. https://doi.org/10.1186/s12966-022-01350-9

Nassajpour, M., Seifallahi, M., Rosenfeld, A., Tolea, M. I., Galvin, J. E., & Ghoraani, B. (2025). Comparison of wearable and depth-sensing technologies with electronic walkway for comprehensive gait analysis. Sensors, 25(17), 5501. https://doi.org/10.3390/s25175501

Nijs, A., Roerdink, M., & Beek, P. J. (2023). Exploring running styles in the field through cadence and duty factor modulation. PLOS ONE, 18(12), e0295423. https://doi.org/10.1371/journal.pone.0295423

Prisco, G., Pirozzi, M. A., Santone, A., Esposito, F., Cesarelli, M., Amato, F., & Donisi, L. (2025). Validity of wearable inertial sensors for gait analysis: A systematic review. Diagnostics, 15(1), 36. https://doi.org/10.3390/diagnostics15010036

Sibson, B. E., Banks, J. J., Yawar, A., Yegian, A. K., Anderson, D. E., & Lieberman, D. E. (2024). Using inertial measurement units to estimate spine joint kinematics and kinetics during walking and running. Scientific Reports, 14, 234. https://doi.org/10.1038/s41598-023-50652-w

Smith, C. P., Fullerton, E., Walton, L., Funnell, E., Pantazis, D., & Lugo, H. (2022). The validity and reliability of wearable devices for the measurement of vertical oscillation for running. PLOS ONE, 17(11), e0277810. https://doi.org/10.1371/journal.pone.0277810

Uno, Y., Ogasawara, I., Konda, S., Yoshida, N., Otsuka, N., Kikukawa, Y., Tsujii, A., & Nakata, K. (2023). Validity of spatio-temporal gait parameters in healthy young adults using a motion-sensor-based gait analysis system (ORPHE ANALYTICS) during walking and running. Sensors, 23(1), 331. https://doi.org/10.3390/s23010331

Verdel, N., Drobnič, M., Maslik, J., Gumiero, A., Hjort, K., Holmberg, H.-C., & Supej, M. (2024). Reliability and validity of running step rate derived from a novel wearable Smart Patch. IEEE Sensors Journal, 24(9), 14343-14351. https://doi.org/10.1109/JSEN.2024.3370304

Wolski, L., Halaki, M., Hiller, C. E., Pappas, E., & Fong Yan, A. (2024). Validity of an inertial measurement unit system to measure lower limb kinematics at point of contact during incremental high-speed running. Sensors, 24(17), 5718. https://doi.org/10.3390/s24175718

Wu, Y., Zhang, H., Wang, S., Lu, C., Xing, Q., Sun, L., & Shen, Y. (2026). Improved running gait parameter estimation from single foot-mounted IMU data based on refined event detection. Frontiers in Bioengineering and Biotechnology, 13, 1714473. https://doi.org/10.3389/fbioe.2025.1714473

Xiang, L., Gao, Z., Wang, A., Shim, V., Fekete, G., Gu, Y., & Fernandez, J. (2024). Rethinking running biomechanics: A critical review of ground reaction forces, tibial bone loading, and the role of wearable sensors. Frontiers in Bioengineering and Biotechnology, 12, 1377383. https://doi.org/10.3389/fbioe.2024.1377383

Yamamoto, M., Shimatani, K., Ishige, Y., & Takemura, H. (2022). Verification of gait analysis method fusing camera-based pose estimation and an IMU sensor in various gait conditions. Scientific Reports, 12, 17719. https://doi.org/10.1038/s41598-022-22246-5

Yuan, Y., Yu, Y., Cai, S., & Cheng, W. (2026). Optimizing wearable IMU configurations for running gait analysis: A machine learning-based sensor fusion approach. Frontiers in Bioengineering and Biotechnology, 14, 1762919. https://doi.org/10.3389/fbioe.2026.1762919

Zeng, Z., Liu, Y., Hu, X., Tang, M., & Wang, L. (2022). Validity and reliability of inertial measurement units on lower extremity kinematics during running: A systematic review and meta-analysis. Sports Medicine - Open, 8, 86. https://doi.org/10.1186/s40798-022-00477-0

Zignoli, A., Godin, A., & Mourot, L. (2023). Indoor running temporal variability for different running speeds, treadmill inclinations, and three different estimation strategies. PLOS ONE, 18(7), e0287978. https://doi.org/10.1371/journal.pone.0287978

Downloads

Published

2026-11-16

How to Cite

Akhmad, I., Suharjo, S., Nurkadri, N., Hariadi, H., & Lubis, A. P. (2026). Criterion agreement and 48-hour test–retest reliability of a microcontroller-based cadence counter during in-place running. Journal of Coaching and Sports Science, 5(4), 31-43. https://doi.org/10.58524/jcss.v5i4.1492